Free calculator

MPPT solar charge controller calculator

You have the panels and you are choosing the controller. The controller has a maximum PV voltage and current, and a cold morning is when the panel voltage is highest. Enter your panel and string, and this page checks the cold Voc and array current against the controller, then shows the charge current, the recommended controller size, the series fuse and the PV cable for the run. Use it as an MPPT sizing calculator, or as a solar charge controller sizing calculator for the panel string you have.

See results ↓

The coefficient defaults to −0.28 %/°C from the Renogy RNG-100D-SS and Rich Solar RS-M200 datasheets. Check your own panel datasheet; panels differ.

Size the panels and battery from your loads · check a DC cable · size a fuse.

Start with the controller limits, not the label

An MPPT controller is sold by its charge current, but two other numbers decide whether it survives your panels. The maximum PV input voltage must stay above the string’s cold-weather open-circuit voltage, and the maximum PV input current must cover the array short-circuit current. A 100 V controller can be a good match on a warm day and still be exceeded on a frosty morning, because panel voltage rises as the temperature falls.

This page is about that panel-string check. If you are still deciding how many panels and how much battery you need, use the RV solar calculator first, then come back here with the panel model you plan to buy.

How the calculator checks your string

Cold Voc. The calculator multiplies one panel’s Voc by the number of panels in series, then applies the datasheet temperature coefficient at your lowest expected temperature. The result is compared with the controller’s maximum PV voltage, with the margin shown. If the cold Voc is above the limit, the page names how many panels fit in series and the next standard controller voltage class.

Array current. The short-circuit current of one string is multiplied by the number of parallel strings and compared with the controller’s maximum PV input current. If you do not know that limit, the page says so instead of guessing; enter it from the controller datasheet.

Charge current and controller size. The array watts are divided by the battery charge voltage (14.4 V for 12 V, 28.8 V for 24 V, 57.6 V for 48 V), then multiplied by 1.25 and rounded up to the next standard controller size. If you enter the controller you already have, the page shows it next to the recommendation.

Series fuses. Three or more parallel strings need a fuse on each string at 1.56 × Isc (NEC 690.9). The fuse must not be above the panel maximum series fuse rating. With one or two strings the page shows a PV disconnect instead.

PV cable. Enter Vmp and the one-way run. The cable is sized for 3% voltage drop and for 1.56 × Isc × strings, using the same free-air PV ampacity table as the app. Without Vmp, the controller checks above still run.

Frequently asked questions

What size MPPT solar charge controller do I need?

Divide the array power by the battery charge voltage, then add the controller margin. Three Renogy 100 W panels in series and two strings (600 W) on a 12 V battery make 41.7 A charge current; 41.7 A × 1.25 = 52.1 A, so the next standard controller is 60 A. The controller also has to accept the string cold Voc and the array Isc.

Can I use five panels in series on a 100 V controller?

Usually not. A 24.3 V panel five in series is 121.5 V at 25 °C. At −10 °C with a −0.28 %/°C coefficient the cold Voc is 133.4 V, above the 100 V limit. The calculator shows that three panels in series (80.0 V cold) fit a 100 V controller, or you need a controller rated at least 150 V.

How is the cold-weather Voc calculated?

Voc × panels in series × (1 + |β| × (25 °C − lowest temperature)). With a 24.3 V panel, β = −0.28 %/°C and −10 °C, the factor is 1.098. Three panels in series give 80.0 V cold; four give 106.7 V. Enter the coefficient from your own panel datasheet.

How much array current can the controller take?

The array short-circuit current is Isc × parallel strings. Four 5.21 A strings give 20.84 A, above a 15 A controller PV input; two strings (10.42 A) fit. Enter the controller maximum PV input current from its datasheet so the page can check it.

When do I need a fuse on each solar string?

With three or more parallel strings, each string needs a fuse of at least 1.56 × Isc (NEC 690.9). A 5.21 A panel needs 8.13 A, so the calculator picks the next standard gPV 10x38 size, 10 A per string, and that fuse must not exceed the panel maximum series fuse rating. With one or two strings the page shows a PV disconnect instead.

Does the calculator size the PV cable?

Yes, when you enter Vmp and the one-way cable run. The page uses the PV circuit rules: 3% voltage drop and ampacity for 1.56 × Isc × strings. It shows the cable size and the PV fuse or disconnect for that run. Without Vmp it still checks the controller voltage and current.

Is this the same as the RV solar calculator?

No. This page checks your panel string against a charge controller: cold Voc, array current, series fuse and PV cable. The RV solar calculator sizes how many panels and how much battery you need from your daily loads. Use both when you plan a full system.