Free calculator

DC fuse size calculator

Size one 12 V or 24 V DC fuse for an ordinary load, a motor or an inverter. Enter current or watts, choose a branch fuse at the busbar or the battery main fuse, and this page returns the fuse rating, type, required current and the cable that carries it — using the same calculation as the OhMyVan app.

What this calculator covers

This page sizes one fuse. A branch fuse sits on the positive busbar and feeds one circuit; the battery main fuse sits on the main positive cable and carries the larger of discharge and charging current. For the main fuse, the page asks for the total discharge current and the total charging current. If your main fuse includes an inverter, take those totals from the OhMyVan app’s main fuse card — the inverter current is set by its low-voltage cutoff and efficiency.

The cable check uses the ampacity table for the insulation class you choose. The suggested cable is the smallest cable that carries the fuse; for a real run, open the 12V wire size calculatorwith the prefilled values to include voltage drop.

How the fuse is chosen

The calculator applies its fuse factor to the design current: 1.25 × for a DC load or inverter and 1.5 × for a motor, then picks the smallest standard fuse at or above that required current. A fuse from your manual replaces the calculated rating. The fuse protects the cable, so the cable ampacity must be at least the fuse rating; the page never suggests a larger fuse than the cable can carry.

Small branch loads follow the same 1.25 × limit as the 12V page: when it is at most the DC fuse block’s per-circuit limit, the page shows a fuse box with ATC/ATO blade fuses. Use the device manual for the exact ATC size; the feed to the fuse box needs its own fuse at the busbar.

Frequently asked questions

How do I size a DC fuse?

Enter the circuit current, or the load watts and the system voltage. The calculator applies its fuse factor (1.25 × for a DC load or inverter, 1.5 × for a motor) and picks the smallest standard fuse at or above that required current. The fuse protects the cable, so the cable ampacity must be at least the fuse rating.

What size fuse for a 12V circuit?

The result depends on the load and the cable. A 30 A DC load needs a 40 A fuse at 1.25 × (37.5 A required), and the cable must carry that 40 A fuse. Use the calculator for the exact number; this page does not guess a fuse from the wire size alone.

Where should the fuse be installed?

Install the fuse in the positive cable at the battery or busbar end, as close to the source as possible (ABYC E-11: within 7 in / 18 cm). A fuse at the load end does not protect the cable.

Can I use the fuse from my device manual?

Yes. Enter it in “Fuse from your manual (A)”. The calculator keeps your rating; if it is below the 1.25 × design current it shows the same nuisance-trip warning as the app. The cable must still carry the fuse you enter.

What about small loads and the DC fuse box?

When 1.25 × the current is at most the DC fuse block’s per-circuit limit (30 A from the shared table), the page shows a fuse box with ATC/ATO blade fuses instead of a MIDI branch fuse. Use the fuse your device manual specifies; the fuse box also needs its own fuse at the busbar end of its feed cable.

Does it size the cable too?

You can enter a cable you already have (AWG or mm²) and the page checks the ampacity rule against the fuse. If you do not enter one, the page shows the smallest cable that carries the fuse. For voltage drop on a real run, use the 12V wire size calculator with the prefilled values.

Why 1.25× for a load and 1.5× for a motor?

The calculator uses 1.25 × the continuous current for DC loads and inverters, and 1.5 × for motors. The spec allows 1.5–2.5 × for motors; check the motor datasheet, because a larger factor may be needed for a hard-starting pump or compressor.

Is this the same result as the app?

The page uses the same calculation as the OhMyVan app. The page covers one fuse and one cable; the full system plan is in the OhMyVan app.