Free calculator
Inverter size calculator
Work out what size inverter your van, camper or RV needs. Add the AC devices you run, choose 12 V, 24 V or 48 V, and this page returns the required watts, the next standard inverter, the start-up surge, the DC current at the low-voltage cutoff, and the branch fuse and cable for the run.
Add at least one AC device to size an inverter.
- Recommended inverter
- —
- Required (continuous × 1.25)
- —
- Continuous AC load
- —
- Surge to plan for
- —
- DC current at full load
- —
- Inverter design voltage
- —
- Branch fuse
- —
- Inverter cable
- —
Fuse location: —. The fuse protects the cable, so the cable ampacity must be at least the fuse rating.
Largest single AC device: —. An inverter must start that device even when it does not run with the others.
How we calculated this
- Continuous AC load
- —
- Largest single AC device
- —
- Required inverter
- —
- Recommended standard size
- —
- Surge to plan for
- —
- DC current
- —
- Cable
- —
- Fuse
- —
- Assumptions
- —
The page uses the load, inverter, wire and fuse rules in the same order as the app, then the gear step for the inverter, fuse, fuse holder and cable. It does not add a formula of its own. The inverter runs at 88% efficiency with a 10 W idle draw; the cable uses the 2.5% inverter drop limit at the low-voltage point. Results assume pure copper cable.
Check the cable run in detail · size the fuse · size the battery · plan solar and MPPT.
Start with the devices, not the inverter
An inverter is sold by its continuous AC output in watts, but the number you need comes from your loads. List the AC devices that can run at the same time and the one device that draws the most on its own. A 1,080 W combination needs a 1,500 W inverter, while the same inverter still has to start the largest single device when everything else is off.
If you are choosing between a small van setup and a full-time rig, the DC current is the number that decides the rest of the system. The 2000 W inverter wire guide walks through the cable and fuse for that case. At 12 V a 2,000 W inverter draws about 216 A at the low-voltage cutoff; at 24 V the same output is about 108 A. That current sets the cable, the fuse and the battery BMS.
How the calculator sizes your inverter
Continuous load. The calculator takes the larger of the simultaneous AC load and the largest single device, multiplies by 1.25, and picks the next standard inverter size from the shared table. The 1.25 margin leaves room for continuous rating tolerances; it is the same rule the app uses.
Surge. Motors and compressors pull a short start-up surge. The page plans for 2 × the simultaneous running load, or the larger combined surge where a preset carries one, and shows that figure. Check the inverter datasheet for its surge rating and how long it holds it.
Why DC current is higher than W ÷ 12. The inverter is not 100% efficient, and its worst-case current is at the low-voltage shutdown point. The calculator divides the selected inverter watts by 88% efficiency and by the design voltage: 10.5 V for 12 V, 21.0 V for 24 V and 37.2 V for 48 V. That is why a 2,000 W 12 V inverter needs about 216 A, not 167 A.
The low-voltage design point. The design voltage is the inverter’s low-battery shutdown, when the battery is lowest and the current is highest. The branch fuse is sized at 1.25 × that DC current and the cable must carry the fuse with 85% headroom and no more than 2.5% drop over the run you enter. The fuse goes at the positive busbar, as close to the battery bank as practical.
The BMS check. A battery BMS has a continuous discharge limit. The page compares that limit, or the 1 C default when no BMS is entered, with the inverter’s full-load DC current. If the limit is lower, the battery cannot carry the inverter alone; use a larger bank, a higher BMS limit, or a higher system voltage.
Frequently asked questions
What size inverter do I need?
Add the AC devices that can run at the same time, plus the largest single device. The calculator multiplies the larger of those two figures by 1.25 and picks the next standard inverter size. For example, a 1,080 W simultaneous load needs 1,350 W and gets a 1,500 W inverter; the largest single device still has to fit even when it runs alone.
How does an inverter size calculator handle surge?
Motors and compressors draw a start-up surge above their running watts. The page starts with 2 × the simultaneous running load, or the sum of the device surge figures where a shared preset has one, and shows the higher figure. Choose an inverter whose surge rating is at least that number and check its surge duration in the datasheet.
Why is the DC current higher than watts divided by 12?
The inverter is not 100% efficient, and the current is highest at the low-voltage shutdown point, not at the nominal battery voltage. The calculator divides the inverter output by efficiency (88% on this page) and by the design voltage (10.5 V for a 12 V system, 21.0 V for 24 V, 37.2 V for 48 V). A 2,000 W inverter at 12 V therefore draws about 216 A, not 167 A.
What fuse and cable does the inverter need?
The page uses the inverter branch rule: a fuse at the positive busbar at least 1.25 × the DC current, and a cable that carries that fuse with 85% headroom and no more than 2.5% voltage drop at the low-voltage point. LiFePO4 gets a Class T branch fuse; AGM follows the MIDI, MEGA or ANL rule. The result also names the fuse location and the cable size for the run you enter.
How do I check the battery BMS?
Enter the battery capacity and, if you know it, the BMS maximum continuous discharge. With no BMS figure the page uses the 1 C default from the shared table. If the limit is below the inverter’s full-load DC current, it shows the same BMS warning as the app; a 100 Ah battery at 1 C cannot carry a 2,000 W 12 V inverter on its own.
Is this a solar inverter size calculator?
It sizes the battery inverter that turns 12 V, 24 V or 48 V DC into AC power. It does not size a grid-tie solar inverter or an MPPT charge controller. For the solar array and MPPT, use the RV solar calculator; for the battery bank, use the battery Ah calculator.
Is this the same result as the app?
The page uses the same calculation as the OhMyVan app; both must pass the same shared tests before a build is allowed. The page sizes the inverter, its branch fuse and cable; the app also carries those parts into the full system plan.