Size one 12 V or 24 V DC circuit in AWG or mm². Enter the current and the one-way cable run, and this page returns the cable size, ampacity, actual voltage drop and the recommended fuse — using the same calculation as the OhMyVan app.
- Cable size
- —
- Cable ampacity
- —
- Voltage drop
- —
- Fuse
- —
- Your cable
- —
- Voltage drop
- —
- Drop check
- —
- Cable ampacity
- —
- Current check
- —
- Fuse headroom
- —
- Recommended for this run
- —
Install the fuse in the positive cable at the battery or busbar end, as close to the source as possible (ABYC E-11: within 7 in / 18 cm). A fuse at the load end does not protect the cable.
Use the fuse your device's manual specifies — compressor fridges and pumps need more than their running current. Never use a fuse larger than the wire to the device can carry. The fuse box needs its own fuse at the busbar end of its feed cable — size that feed for the total of all loads on the box.
How we calculated this
Voltage drop uses the round-trip length (2 × the one-way run). The calculator picks the smallest standard cable that satisfies both the allowed voltage drop and the fuse-current ampacity.
- Allowed voltage drop
- —
- Required by voltage drop
- —
- Cable by voltage drop
- —
- Cable by ampacity
- —
- Fuse required (1.25 × current)
- —
- Assumptions
- —
Imperial drop uses circular mils (K = 10.75 for copper); metric uses mm² (ρ = 0.0175 Ω·mm²/m). The cable must also carry the fuse current with ampacity ≥ fuse ÷ 0.85. These are the calculator’s documented rules, not a separate calculation on this page.
Results assume pure copper cable. Copper-clad aluminum (CCA) carries less current — do not use it with these sizes.
What this calculator covers
This page is deliberately limited to one DC circuit: a positive and negative cable from the battery or busbar to one load. It does not replace the full system plan. An inverter cable is sized at the inverter’s low-voltage cutoff, and the main battery cable carries both charging and discharge current — the OhMyVan app handles those runs.
Need only the fuse size? Use the DC fuse size calculator.
12 V voltage drop calculator: check a cable you already have
If you already own a cable, choose Check my cable at the top of the tool and pick its AWG or mm² size. The page shows the voltage drop for your run, a pass or fail against the 3% or 10% target, the cable ampacity against your current, and whether the cable leaves 85% headroom for the fuse. When a check fails, it names the size the calculator would use instead. No new page or formula — the same shared tables and rules drive both modes.
How the cable and fuse are chosen
The calculator first converts the allowed voltage drop into a required copper area, then checks the cable ampacity against the fuse current with 85% headroom. The larger of the two cable candidates wins. The fuse is the smallest standard size at or above 1.25 × the circuit current and at most 85% of the chosen cable’s ampacity (ampacity ≥ fuse ÷ 0.85).
Voltage drop is 3% of the 12.0 V or 24.0 V LiFePO4 design voltage for a critical circuit, or 10% for a non-critical circuit. The first size in the standard table that meets both rules is shown.
Frequently asked questions
How do I size a 12V wire?
Enter the current the circuit draws and the one-way cable length. The calculator picks the smallest standard cable that keeps the voltage drop under 3% (critical) or 10% (non-critical) and also carries the fuse current. It shows the AWG or mm² size, the cable ampacity and the actual voltage drop.
Does the cable length include the return run?
No. Enter the one-way length only; the calculator doubles it because DC current flows out to the load and back through the negative cable.
What voltage drop should a 12V DC circuit have?
This page uses 3% for a critical circuit and 10% for a non-critical one, measured at the 12.0 V or 24.0 V LiFePO4 design voltage. The result shows the allowed drop in volts and the actual drop in volts and percent.
How much voltage drop is OK on 12 V?
This page uses 3% for a critical circuit, which is 0.36 V at the 12.0 V design voltage, and 10% for a non-critical circuit, which is 1.20 V. For example, 10 AWG cable on a 15 ft one-way run at 30 A drops 0.93 V (7.8%) — over the 3% target. The same calculator passes 8 AWG on a 3 ft run at 32.5 A at 0.13 V (1.1%).
How do I calculate voltage drop on a 12 V cable?
Enter the one-way run and the current in Find the right cable, or enter your installed size in Check my cable. The calculator uses the round-trip length (2 × the one-way run), the copper resistance and the cable area, then compares the result with the 3% or 10% target. For example, 10 AWG at 30 A over 15 ft one way gives 0.93 V (7.8%).
Can I use a cable I already have?
Yes. Choose Check my cable and pick the AWG or mm² size you have. The page shows the voltage drop, whether it meets the target, the cable ampacity against the current, and the fuse headroom. A 12 AWG cable over 3 ft at 30 A drops 0.30 V (2.47%) and passes the 3% target, but a 40 A fuse needs 47 A of cable ampacity with the 85% headroom rule; 12 AWG is rated 40 A, so the fuse check fails and 10 AWG is recommended.
What cable insulation should I choose?
Standard 90 °C is the default. Choose Marine 105 °C only when the installed cable is rated 105 °C. The Hot space option applies the hot-space (engine-bay) correction factor from ISO 13297 to the selected cable. Results assume pure copper cable. Copper-clad aluminum (CCA) carries less current — do not use it with these sizes.
Does it size the fuse too?
Yes. When the cable has no errors, the calculator uses the same rule for a fuse at least 1.25 × the circuit current and at most 85% of the cable ampacity (ampacity ≥ fuse ÷ 0.85). The fuse type is shown with the rating.
Is this the same result as the app?
The page uses the same calculation as the OhMyVan app. This page covers one DC circuit; inverter cables and the main battery cable are sized in the OhMyVan app.